Quantcast
Channel: All ONTAP Discussions posts
Browsing all 19253 articles
Browse latest View live

Re: NTP time sync issue - done everything to resolve but no go....

When is the last time the controller has been rebooted? I'm just curious. Also, I would use the date command to set the date and then turn off time off and on options timed.enable off options...

View Article


Re: NetApp-Harvest manager poll error

have same problem on new installation of harvest. Version 1.2.2cDOT 8.3 and 8.3.1P1 ======= Update ==========after reinstalling Virtual appliance and importing netapp-harvest.conf file, it...

View Article


Re: Broken Disk shown

To this today, i still dont' understand how people run RC code in production.   It boggles my mind.. You should look into upgrading when you get your shelf/disk fixed.  And I would call support

View Article

windows file server migration to netapp cluster mode FAS2552

Hi Experties, I want to perform migration of one of the file share folder from the existing windows file server to the newly setup netapp FAS2552 (two node cluster) CIFS share. currently windows file...

View Article

Re: Does Data Ontap support ADP for Flash Pool in an Infinite Volume?

Yes, it is supported. However the performance benifit might not be as good as it is with a regular volume.Also refer...

View Article


Re: windows file server migration to netapp cluster mode FAS2552

Hi Sid,  May i know the size of the share, How about  Robocopy ( Windows ) it would be the ideal option. Steps Would be:- 1) Create a cifs share in Netapp storage of same size or higher than your...

View Article

Image may be NSFW.
Clik here to view.

7MTT Unable to fetch details from Windows 2012 R2 Datacenter

Hi All, I am having this error, while trying to add my localhost to 7MTT  7MTT Version :- 2.1 Windows Version :- 2012 R2 Datacenter     Thanks,Nayab

View Article

Changing INTERCLUSTER LIF ip addresses on all clusters

Hi, We are moving our intercluster WAN from 10.x.x.x.x address range to say 192.x.x.x.x. we have 3 clusters and all have multiple intercluster LIFS. is changing the ip as simple as modiying the current...

View Article


Image may be NSFW.
Clik here to view.

Re: Keep the same SVM name as primary when do DR test

You cannot have same SVM name at Source and Destination as i have tried in my LAB and got the error below  Cluster1 is my Source Cluster and Cluster2 is my destination  I used the same SVM name "...

View Article


Re: 7MTT Unable to fetch details from Windows 2012 R2 Datacenter

Hi Nayabsk, Can you try adding local windows machine with actual IP or FQDN name (instead of localhost)Please let us know if that works. ThanksSR 

View Article

Image may be NSFW.
Clik here to view.

Re: 7MTT Unable to fetch details from Windows 2012 R2 Datacenter

I tried it already but still the same error

View Article

Limit the number of dedupe jobs running in parallel (7-Mode)

In 7-Mode only schedules for dedupe jobs are possible beginning at full hours e. g. 8:00am 10:00pm etc. Having numerous jobs it leads to situations where up to 8 jobs are running during the first...

View Article

Found this on serverfault --- looked like it might be the...

Found this on serverfault --- looked like it might be the same OP. Anyway, here is how I got this working on Cluster mode 8.3 (plagiarized from the serverfault posting):First you have to add publickey...

View Article


Re: How to configure NFS logging

Dear All, I have a similar issue as well and currently stuck with the NFS auditing. We have peculiar requirement, where one of your export is widely shared across multiple host as per design. Here...

View Article

Without show "vtic", is that normal?

I remember where should be alway a "vtic" after logged in, and along with a port number, in (logged in). How come don't I see it in the following command? I am using 8.3.1 Thanks! cluster::> igroup...

View Article


Re: Without show "vtic", is that normal?

In C-Mode multipath implementation is different, so there is no "vtic".

View Article

Re: Without show "vtic", is that normal?

vtic means the partner target port in 7-mode, how could it be difference in cDOT mode? how could the partner target port be represented in cD0T?

View Article


CIFS Error: Nblade.cifsMaxWatchesPerTree: Received too many Change Notify...

I've recently started getting these errors: Nblade.cifsMaxWatchesPerTree: Received too many Change Notify requests on one tree: clientIP:port 192.168.1.51:57914, directory "<directory>" on share...

View Article

force delete SVM - ipspace shows SVM-name

Hello I'm not managing to delete a SVM because it linked to DEFAULT ipspace that is being using by other resource. There is a way to force delete SVM? Thank you very much. -MRF

View Article

cDOT - Using mixed SAN / NAS SVMs

While cDOT SVM/Vservers have always allowed any mix of NAS and SAN protocols, over time a 'best-practice' seems to have developed that one should keep these two types of protocols segregated in...

View Article
Browsing all 19253 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>